Rakhial, Ahmedabad, Gujarat
GST No. 24EBHPP7208D1ZR
Call 08048271931 77% Response Rate
Send Enquiry
Minimum Order Quantity: 1 Piece
Product Brochure
| Sensor Type | Flow Sensors |
| Brand | IFm |
| Part Number | SI5000 SID10ABBFPKG/US-100 |
| Application | Industrial |
| Flow Rate | Liquids (e.g., water, oil) 3 to 300 cm/s Gases (e.g., air, nitrogen) 200 to 3000 cm/s |
| Supply Voltage | 18-36 V DC |
| Material | Stainless Steel |
| Number of inputs and outputs | Number of digital outputs: 1 |
| Process connection | threaded connection M18 x 1,5 internal thread |
| Media | Liquids; Gases |
| Medium temperature [ DegreeC] | -25...80 |
| Pressure rating | 30 bar 3 MPa |
| Liquids Medium temperature [ DegreeC] | -25...80 |
| Gases Medium temperature [ DegreeC] | -25...80 |
| Operating voltage [V] | 19...36 DC |
| Current consumption [mA] | < 60 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 10 |
| Output signal | switching signal |
| Electrical design | PNP |
| Output function | normally open / normally closed |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 250 |
| Short-circuit protection | Yes |
| Type of short-circuit protection | Pulsed |
| Overload protection | Yes |
| Probe length L [mm] | 45 |
| Protection | IP 67 |
| Weight [g] | 246 |
| Housing | cylindrical |
| Dimensions [mm] | 50 / L = 113 |
The IFM SI5000 is a compact, robust flow monitor designed for precise detection and monitoring of liquid and gaseous media in pipes. It uses calorimetric sensing technology to ensure reliable and maintenance-free operation without moving parts, making it ideal for industrial automation and process control applications.
Applications:
Monitoring coolant or lubrication flow in machinery
Air flow detection in pneumatic systems
Dry-run protection for pumps
General flow detection in water treatment and process automation
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Sensor Type | Flow Sensors |
| Brand | IFM |
| Part Number | SI6800 SIR11ABBFPKG/US-100-IPF |
| Application | Industrial |
| Flow Rate | Liquids 3 to 300 cm/s Gases 200 to 3000 cm/s |
| Supply Voltage | 19-36 V DC |
| Material | Stainless Steel |
| Number of inputs and outputs | Number of digital outputs: 1 |
| Process connection | threaded connection G 1 external thread Aseptoflex Vario |
| Special feature | Gold-plated contacts |
| Medium temperature [ DegreeC] | -25...95; (for SIP process: ...140 DegreeC) |
| Pressure rating | 30 bar 3 MPa |
| MAWP for applications according to CRN [bar] | 30 |
| Operating voltage [V] | 19...36 DC |
| Current consumption [mA] | < 60 |
| Protection class | III |
| Reverse polarity protection | Yes |
| Power-on delay time [s] | 10 |
| Output signal | switching signal |
| Electrical design | PNP |
| Output function | normally open / normally closed |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 250 |
| Short-circuit protection | Yes |
| Type of short-circuit protection | Pulsed |
| Overload protection | yes |
| Probe length L [mm] | 55 |
| Protection | IP 67; IP 69K |
| Weight [g] | 440 |
| Housing | cylindrical |
| Dimensions [mm] | 50 / L = 154 |
The IFM SI6800 is a compact electronic flow monitor designed to detect and monitor the flow of liquids and gases in industrial and hygienic applications. This device operates using the calorimetric measuring principle, ensuring no moving parts and therefore high reliability and low maintenance.
Typical Applications:
CIP/SIP process line monitoring
Pump protection (dry run prevention)
Flow detection in cooling, lubrication, or filtration circuits
Detection of flow loss or blockage in pipe systems
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Mounting Type | Bolt Mount |
| Number of inputs and outputs | Number of digital outputs: 2 |
| Factory setting | automatic media detection |
| Probe length L [mm] | 264 |
| Special feature | Gold-plated contacts |
| Media | hydrous coolants; oils; oil-based media; water; media similar to water |
| Dielectric constant of the mediumq | > 2 |
| Cannot be used for | extremely conductive media; adhering media; granulates; bulk material; acids; alkali; hygienic area |
| Maximum speed of the change of level [mm/s] | 100 |
| Coolants Medium temperature [ DegreeC] | 0...35; (with climatic tube E43100: 35...65 DegreeC) |
| Oil Medium temperature [ DegreeC] | 0...70 |
| Water Medium temperature [ DegreeC] | 0...35 |
| Operating voltage [V] | 12...30 DC |
| Current consumption [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | Yes |
| Output signal | switching signal; IO-Link |
| Electrical design | PNP/NPN |
| Output function | normally open / normally closed |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 200 |
| Type of short-circuit protection | thermal, pulsed |
| Protection | IP 67 |
| Weight [g] | 289.6 |
| Dimensions [mm] | 16 |
| Materials | stainless steel |
Continuous level measurement in machine coolants, water, oil reservoirs, and process tanks
OEM machinery, hydraulic systems, tool-room reservoirs
Industrial settings needing clear local readouts and remote IO-Link reporting
Additional Information:
View Complete details